In order to obtain the radioactivity concentration information of the nuclides in the process of disposal of low level waste, an analytical method for the determination of 55Fe in spent ion-exchange resin was established by using TRU resin as the separation and purification material and liquid scintillation spectrometry method. The chemical recovery of Fe for this method is approximately 87.23%, and the minimum detectable specific activity is approximately 11.43 mBq/g. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Nuclear and Radiochemistry
Journal Volume
42
Journal Issue
2
Journal Page Range
p. 116-120
ISSN
0253-9950

Optional Information

Notes
3 figs., 5 tabs., 8 refs.; http://dx.doi.org/10.7538/hhx.2020.YX.2019026