Published November 1975 | Version v1
Report Restricted

Flow patterns in high pressure two-phase flow: a visual study of water in a uniformly heated 4-rod bundle (LWBR Development Program)

Description

Flow patterns that occur in a rod bundle with forced upward flow of boiling water have been photographed. The experimental rod bundle consisted of four vertical 0.25-inch diameter by 24.0 inch long rods arranged in a single row. The tested conditions were: pressure--400 to 2000 psia, mass velocity--250,000 to 4,000,000 lb/hr-ft2, and heat flux (uniform)--up to 1,600,000 Btu/hr-ft2. The observed two-phase flow patterns were bubble flow, froth flow, slug flow, and annular flow. The flow patterns were mapped at constant pressure on plots of mass velocity versus flowing quality

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
LWBR

Publishing Information

Imprint Pagination
83 p.
Report number
WAPD-TM--1199