Predicted performance of the LCLS x-ray diagnostics

  • 1. Advanced Photon Source, Argonne National Laboratory, 9700 S. Cass Ave., Argonne, Illinois 60439 (United States)

Description

An x-ray diagnostics concept is proposed for the Linac Coherent Light Source (LCLS). X-ray diagnostics will provide spectral and spatial measurements of the spontaneous and SASE radiation along the undulator line, and will be complimentary to an electron beam diagnostics. Main goal of the x-ray diagnostics is to measure the radiation gain along the undulator line. Diagnostics setup consists of diamond crystal monochromator and silicon PIN diode and CCD camera detectors. Accuracy and dynamic ranges of x-ray diagnostics are discussed

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
581
Journal Issue
1
Journal Page Range
p. 131-140
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
Physics of and science with the X-ray free-electron laser
Acronym
19. ICFA advanced beam dynamics workshop on future light sources
Dates
10-15 Sep 2000
Place
Arcidosso (Italy)

Optional Information

Notes
(c) 2001 American Institute of Physics.