Published March 2005 | Version v1
Miscellaneous

Development of an ultra precision aspherical profiler for synchrotron radiation mirror. Calibration of the angle positioning for the goniometer

  • 1. Osaka University, Research Center for Ultra-Precision Science and Technology, Suita, Osaka (Japan)
  • 2. High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

Description

A new ultra-precision profiler has been developed in order to measure such as asymmetric and aspheric profiles. In the present study, the normal vectors at each points on the surface are determined by the reflected light beam goes back exactly on the same path as the incident beam. The surface gradients at each point are calculated from the normal vector and the surface profile is obtained by integrating the gradient. The measuring instrument was designed according to the above principle of the measuring method. In the design, four ultra-precision goniometers were applied to adjust of the light axis for the normal vector measurement. In the present measuring, the most important item is the measuring accuracy of the normal vectors by the goniometers. Therefore, the rotating angle positioning errors were measured and calibrated. In this paper, the calibration method is described. And evaluate the results of the measuring accuracy. (author)

Part of:
Proceedings of 2005 Japan Society for Precision Engineering spring conference

Additional details

Additional titles

Original title (Japanese)
2005 seimitsu-kogakkai shunki taikai gakujutsu koenkai koen ronbunshu

Publishing Information

Imprint Title
Proceedings of 2005 Japan Society for Precision Engineering spring conference
Imprint Pagination
1366 p.
Journal Page Range
p. 1029-1030

Conference

Title
2005 Japan Society for Precision Engineering spring conference
Dates
16-18 Mar 2005
Place
Yokohama, Kanagawa (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
42077393
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCURACY; CALIBRATION; GONIOMETERS; LASER RADIATION; MIRRORS; OPTICAL REFLECTION; OPTICAL SYSTEMS; POSITIONING; ROTATION; SURFACE PROPERTIES; SYNCHROTRON RADIATION
Descriptors DEC
BREMSSTRAHLUNG; ELECTROMAGNETIC RADIATION; MEASURING INSTRUMENTS; MOTION; RADIATIONS; REFLECTION

Optional Information

Notes
Imprint:This CD-ROM can be used for WINDOWS 9x/NT/2000/ME/XP/VISTA, MACINTOSH; Acrobat Reader is included; Data in PDF format, Folder Name pdf, Paper ID L33.pdf