Sensitivity analysis to evaluate the transport properties of CdZnTe detectors using alpha particles and low-energy gamma-rays

  • 1. Dept. of Nuclear Engineering, Hanyang University, Seoul(Korea, Republic of)
  • 2. Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)
  • 3. RADCORE Co., Ltd, Daejeon (Korea, Republic of)
  • 4. Advanced Radiation Detection Instrument and Sensor Lab, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (α particle and gamma-ray) emitted from an '241Am source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector (5 x 5 x 2 mm3) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from (α particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (μτ) products; the α particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the α particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than α particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Technology
Journal Volume
43
Journal Issue
6
Series
17 refs, 4 figs, 2 tabs
Journal Page Range
p. 567-572
ISSN
1738-5733

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
44090668
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CADMIUM ALLOYS; ENERGY SPECTRA; GAMMA RADIATION; SENSITIVITY ANALYSIS; TELLURIUM ALLOYS; TRANSPORT; ZINC ALLOYS
Descriptors DEC
ALLOYS; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATIONS; SPECTRA