Published July 1977 | Version v1
Journal article

Coincidence counting of I-129; some remarks on the efficiency extrapolation technique in coincidence counting; a determination of the efficiency of a methane 4π-counter to 32 keV photons

  • 1. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Lab. de Metrologie des Rayonnements Ionisants

Description

Several methods of coincidence counting of 129I are examined. Efficiency functions are estimated for these different methods and compared with the results of experiments leading to the indication of the most suitable conditions of measurements. It was also found that the γ-efficiency of the 4πβ methane flow counter for photons near 32 keV was 0.024 +- 0.005. Finally some general remarks are made on the extrapolation technique as used for coincidence counting. (author)

Additional details

Identifiers

Publishing Information

Journal Title
The International Journal of Applied Radiation and Isotopes
Journal Volume
28
Journal Issue
7
Series
Int. J. Appl. Radiat. Isot.
Journal Page Range
615-624
ISSN
0020-708X

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent