Published March 28, 2016 | Version v1
Journal article

Phase-contrast MRI volume flow – a comparison of breath held and navigator based acquisitions

  • 1. Department of Clinical Physiology, Linkoping University, SE-603 79 Norrkoping (Sweden)
  • 2. Center for Medical Image Science and Visualization, Linkoping University, SE-581 83 Linkoping (Sweden)
  • 3. Department of Diagnostic Radiology, Linkoping University, SE-581 85 Linkoping (Sweden)
  • 4. Department of Clinical Physiology, Linkoping University, SE-581 85 Linkoping (Sweden)
  • 5. Department of Medical and Health Sciences, Linkoping University, SE-581 83 Linkoping (Sweden)

Description

Magnetic Resonance Imaging (MRI) 2D phase-contrast flow measurement has been regarded as the gold standard in blood flow measurements and can be performed with free breathing or breath held techniques. We hypothesized that the accuracy of flow measurements obtained with segmented phase-contrast during breath holding, and in particular higher number of k-space segments, would be non-inferior compared to navigator phase-contrast. Volumes obtained from anatomic segmentation of cine MRI and Doppler echocardiography were used for additional reference. Forty patients, five women and 35 men, mean age 65 years (range 53–80), were randomly selected and consented to the study. All underwent EKG-gated cardiac MRI including breath hold cine, navigator based free-breathing phase-contrast MRI and breath hold phase-contrast MRI using k-space segmentation factors 3 and 5, as well as transthoracic echocardiography within 2 days. In navigator based free-breathing phase-contrast flow, mean stroke volume and cardiac output were 79.7 ± 17.1 ml and 5071 ± 1192 ml/min, respectively. The duration of the acquisition was 50 ± 6 s. With k-space segmentation factor 3, the corresponding values were 77.7 ml ± 17.5 ml and 4979 ± 1211 ml/min (p = 0.15 vs navigator). The duration of the breath hold was 17 ± 2 s. K-space segmentation factor 5 gave mean stroke volume 77.9 ± 16.4 ml, cardiac output 5142 ± 1197 ml/min (p = 0.33 vs navigator), and breath hold time 11 ± 1 s. Anatomical segmentation of cine gave mean stroke volume and cardiac output 91.2 ± 20.8 ml and 5963 ± 1452 ml/min, respectively. Echocardiography was reliable in 20 of the 40 patients. The mean diameter of the left ventricular outflow tract was 20.7 ± 1.5 mm, stroke volume 78.3 ml ± 15.2 ml and cardiac output 5164 ± 1249 ml/min. In forty consecutive patients with coronary heart disease, breath holding and segmented k-space sampling techniques for phase-contrast flow produced stroke volumes and cardiac outputs similar to those obtained with free-breathing navigator based phase-contrast MRI, using less time. The values obtained agreed fairly well with Doppler echocardiography while there was a larger difference when compared with anatomical volume determinations using SSFP (steady state free precession) cine MRI

Availability note (English)

Available from http://dx.doi.org/10.1186/s12880-016-0128-x; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4809032

Additional details

Publishing Information

Journal Title
BMC Medical Imaging (Online)
Journal Volume
16
Journal Page Range
vp.
ISSN
1471-2342

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47120345
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BLOOD CIRCULATION; BLOOD FLOW; BREATH; CARDIOVASCULAR DISEASES; MAGNETIC RESONANCE; NMR IMAGING; PATIENTS; RESPIRATION
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DISEASES; RESONANCE

Optional Information

Copyright
Copyright (c) Andersson et al. 2016
Notes
PMCID: PMC4809032; PMID: 27021353; PUBLISHER-ID: 128; OAI: oai:pubmedcentral.nih.gov:4809032