Description

Purpose: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. Methods and Materials: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso (registered) System for quantification of intrafraction setup error. Results: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. Conclusion: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2010.02.001

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2010.02.001;
PII
S0360-3016(10)00223-3;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
78
Journal Issue
5
Journal Page Range
p. 1579-1585
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42083203
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; MOTION; NEOPLASMS; PELVIS; PLANNING; POSITIONING; PROSTATE; RADIOTHERAPY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.