Published May 2008 | Version v1
Journal article

A MAPS-based readout of an electromagnetic calorimeter for the ILC

  • 1. School of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom)
  • 2. Department of Physics, Imperial College, London (United Kingdom)
  • 3. STFC-Rutherford-Appleton Laboratory, Chilton, Didcot (United Kingdom)

Description

The physics goals of the International Linear Collider (ILC) require a significant improvement in the calorimetric performance relative to previous generations of detectors. Sampling electromagnetic calorimeters (ECAL) using silicon diodes as the active media are widely considered as a suitably performant-but very expensive-solution. A new digital approach to electromagnetic calorimeter design based on 50 μm pitch Monolithic Active Pixel Sensors is presented as an alternative solution which could offer (at least) the same performance at significantly reduced cost

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/110/9/092035

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
110
Journal Issue
9
Journal Page Range
[3 p.]
ISSN
1742-6596

Conference

Title
2007 Europhysics conference on high energy physics
Dates
19-25 Jul 2007
Place
Manchester (United Kingdom)