Dynamic testing of POSI-SEAL motor-operated butterfly valves using strain gages
Creators
Description
Utilities operating nuclear power plants recognize that the correct functioning of all motor-operated valves, and particularly those in safety-related systems, is of paramount importance. The U.S. Nuclear Regulatory Commission has issued Generic Letter 89-10 relative to this concern. Operability must be demonstrated under design-basis conditions. In order to demonstrate operability of motor-operated butterfly valves, the valve stem torque must be determined. The valve stem torque is a function of seat material, stem packing, stem bearing friction, and hydrodynamic lift and drag. The total valve operating hydrodynamic torque can be predicted using the valve manufacturer's data and the differential pressure. In order to validate the valve manufacturer's data, the actual total valve hydrodynamic torque is measured using strain gages mounted directly on the valve stem. This paper presents the results of comparing the predicted total valve operating hydrodynamic torque with the actual total valve operating hydrodynamic torque for six POSI-SEAL Class 150 high performance butterfly valves
Additional details
Publishing Information
- Imprint Title
- Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Volume 2, Session 3A--Session 4B
- Imprint Pagination
- 353 p.
- Journal Page Range
- p. 155-162.
- Report number
- NUREG/CR--0137-Vol.2
Conference
- Title
- 3. international symposium on fusion nuclear technology.
- Acronym
- ISFNT-3
- Dates
- 27 Jun - 1 Jul 1994.
- Place
- Los Angeles, CA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26033584
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- IN-SERVICE INSPECTION; NUCLEAR POWER PLANTS; REACTOR COMPONENTS; RELIABILITY; TESTING; VALVES
- Descriptors DEC
- CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; INSPECTION; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS
Optional Information
- Secondary number(s)
- EGG--2742-Vol.2; CONF-940664--Vol.2.