Published January 1, 2012 | Version v1
Journal article

Comparison of Macroscopic Pathology Measurements With Magnetic Resonance Imaging and Assessment of Microscopic Pathology Extension for Colorectal Liver Metastases

  • 1. Department of Radiation Oncology, Erasmus MC–Daniel den Hoed Cancer Center, Rotterdam (Netherlands)
  • 2. Department of Pathology, Erasmus MC–Daniel den Hoed Cancer Center, Rotterdam (Netherlands)
  • 3. Department of Radiology, Erasmus MC–Daniel den Hoed Cancer Center, Rotterdam (Netherlands)
  • 4. Institute for Medical Technology Assessment, Erasmus University, Rotterdam (Netherlands)
  • 5. Department of Surgery, Erasmus MC–Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

Description

Purpose: To compare pathology macroscopic tumor dimensions with magnetic resonance imaging (MRI) measurements and to establish the microscopic tumor extension of colorectal liver metastases. Methods and Materials: In a prospective pilot study we included patients with colorectal liver metastases planned for surgery and eligible for MRI. A liver MRI was performed within 48 hours before surgery. Directly after surgery, an MRI of the specimen was acquired to measure the degree of tumor shrinkage. The specimen was fixed in formalin for 48 hours, and another MRI was performed to assess the specimen/tumor shrinkage. All MRI sequences were imported into our radiotherapy treatment planning system, where the tumor and the specimen were delineated. For the macroscopic pathology analyses, photographs of the sliced specimens were used to delineate and reconstruct the tumor and the specimen volumes. Microscopic pathology analyses were conducted to assess the infiltration depth of tumor cell nests. Results: Between February 2009 and January 2010 we included 13 patients for analysis with 21 colorectal liver metastases. Specimen and tumor shrinkage after resection and fixation was negligible. The best tumor volume correlations between MRI and pathology were found for T1-weighted (w) echo gradient sequence (rs = 0.99, slope = 1.06), and the T2-w fast spin echo (FSE) single-shot sequence (rs = 0.99, slope = 1.08), followed by the T2-w FSE fat saturation sequence (rs = 0.99, slope = 1.23), and the T1-w gadolinium-enhanced sequence (rs = 0.98, slope = 1.24). We observed 39 tumor cell nests beyond the tumor border in 12 metastases. Microscopic extension was found between 0.2 and 10 mm from the main tumor, with 90% of the cases within 6 mm. Conclusions: MRI tumor dimensions showed a good agreement with the macroscopic pathology suggesting that MRI can be used for accurate tumor delineation. However, microscopic extensions found beyond the tumor border indicate that caution is needed in selecting appropriate tumor margins.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2010.10.032

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2010.10.032;
PII
S0360-3016(10)03455-3;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
82
Journal Issue
1
Journal Page Range
p. 159-166
ISSN
0360-3016
CODEN
IOBPD3

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.