Optimized probes for dose rate measurements at local government sites and in emergency planning zones and their integration into measurement networks
- 1. National Radiation Protection Institute, Prague (Czech Republic)
- 2. ENVINET, Trebic (Czech Republic)
Description
The results of a security project aimed at the development of a radiation situation monitoring system using optimized probes for dose rate measurements are described. The system is suitable for use at local government sites as well as at other sites. The system includes dose rate measurement probes with the variable configuration functionality (detection part), equipment for data transfer to a central workplace (communication part) and application for collection, storage and administration of the results and their presentation at a website (presentation part). The dosimetric and other operational properties of the probes were tested and the feasibility of their integration into measurement networks using the IMS central application was examined. (orig.)
Additional details
Additional titles
- Original title (Czech)
- Optimalizované sondy pro měření dávkového příkonu určené pro samosprávu a ZHP a jejich integrace do měřicích sítí
Publishing Information
- Journal Title
- Bezpecnost Jaderne Energie
- Journal Volume
- 23
- Journal Issue
- 5-6
- Journal Page Range
- p. 163-168
- ISSN
- 1210-7085
INIS
- Country of Publication
- Czech Republic
- Country of Input or Organization
- Czech Republic
- INIS RN
- 46067103
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- DATA TRANSMISSION; EMERGENCY PLANS; PROBES; RADIATION MONITORING; RADIATION MONITORS; TESTING
- Descriptors DEC
- COMMUNICATIONS; MEASURING INSTRUMENTS; MONITORING; MONITORS
Optional Information
- Notes
- 16 figs., 7 refs.