Published April 1, 1997 | Version v1
Journal article

Impact of setup variability on incidental lung irradiation during tangential breast treatment

Description

Purpose: This study aimed to determine the variability in treatment setup during a 5-week course of tangential breast treatment for patients immobilized in a customized hemibody cradle, to assess the relationship between the height of the lung shadow on the tangential port film and the percentage of lung volume irradiated, and to estimate the impact of setup variabilities on irradiated lung volume. Methods: One hundred seventy-two port films were reviewed from 20 patients who received tangential beam treatment for breast cancer. The height of the lung shadow at the central axis (CLD) on each port film was compared to the corresponding simulator film as an assessment of setup variability. A three-dimensional dose calculation was performed, and the percentage of total lung volume within the field was correlated with the CLD. The three-dimensional dose calculation was repeated for selected patients with the location of the treatment beams modified to reflect typical setup variations. Results: The CLD measured on the port films was within 3 mm of that prescribed on the simulator film in 43% (74 of 172) of the port films. The variation was 3-5 mm in 26%, 5-10 mm in 25%, and >10 mm in 6%. The height of the lung shadow correlated with the percentage of lung volume included in the radiation field (r2 = 0.6). Typical variations in treatment setup resulted in ≤5% fluctuation in the absolute volume of ipsilateral lung irradiated. Conclusion: The current immobilization system used in our clinic provides a clinically acceptable reproducibility of patient setup. The height of the lung shadow is reasonably well correlated with the percentage of irradiated lung volume. During a typical 5-week course of radiotherapy, the ipsilateral irradiated lung volume fluctuates <5%

Additional details

Identifiers

PII
S0360301697002332;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
38
Journal Issue
1
Journal Page Range
p. 109-115
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35009165
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOLOGICAL RADIATION EFFECTS; EXTERNAL IRRADIATION; IRRADIATION PROCEDURES; LUNGS; MAMMARY GLANDS; NEOPLASMS; VOLUME
Descriptors DEC
BIOLOGICAL EFFECTS; BODY; DISEASES; GLANDS; IRRADIATION; ORGANS; RADIATION EFFECTS; RESPIRATORY SYSTEM

Optional Information

Copyright
Copyright (c) 1997 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.