Published 1991
| Version v1
Report
Evaluation of measurement data from continuous calibration procedures at an input accountancy tank
Creators
- 1. Wiederaufarbeitungsanlage Karlsruhe Betriebsgesellschaft mbH (WAK), Eggenstein-Leopoldshafen (Germany)
- 2. Gesellschaft fuer Nuklear-Service, Hannover (Germany)
Description
One of the essential aims of the CALDEX project is the comparative evaluation of the conventional tank calibration procedure using an incremental addition of liquor and of the calibration with a continuous liquid feed. The three calibration exercises performed with water in continuous mode have been evaluated. Estimates of volume determination uncertainty are given for all manometers which can be compared with the evaluations from other calibration procedures
Additional details
Publishing Information
- Imprint Title
- Safeguards and nuclear material management
- Imprint Pagination
- 745 p.
- Journal Page Range
- p. 597-602.
- Report number
- EUR--13686
Conference
- Title
- 13. Annual Symposium on Safeguards and Nuclear Material Management.
- Dates
- 14-16 May 1991.
- Place
- Avignon (France).
INIS
- Country of Publication
- European Commission (EC), Brussels (Belgium)
- Country of Input or Organization
- European Commission (EC), Brussels (Belgium)
- INIS RN
- 23087973
- Subject category
- S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; DATA COVARIANCES; FLOW RATE; LEVEL INDICATORS; TANKS; WEIGHT INDICATORS
- Descriptors DEC
- CONTAINERS; MEASURING INSTRUMENTS