Published December 1985 | Version v1
Journal article

Choice of main parameters for district heating networks of power-and-heat plants

  • 1. 6762880SU

Description

Results of determining basic parameters of nuclear power-and-heat plant (NPHP) based district heating with two WWER-1000 reactors and four extraction turbines are given. For 1400 mm diameters of transit main lines an optimal version is the version with water temperature of 140-150 deg C in transit main line at NPHP thermal load of 2800 MJ/s, at that water flow rate constitutes 29000-26000 t/h. With increase of transit distance an optimal estimated thermal load of NPHP decreases and water temperature enhances

Additional details

Additional titles

Original title (Russian)
Выбор основных параметров систем теплоснабжения ATEhTs

Publishing Information

Journal Title
Teploehnergetika
Journal Issue
no.12
Series
Teploehnergetika.
ISSN
0040-3636
CODEN
TPLOA

Optional Information

Notes
For English translation see the journal Thermal Engineering (UK).