Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women

  • 1. Krankenhaus der Volkspolizei Berlin (German Democratic Republic)
  • 2. Humboldt-Universitaet, Berlin (German Democratic Republic). Bereich Medizin (Charite)

Description

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography

Additional details

Additional titles

Original title (German)
Vergleichende Strahlendosismessungen zwischen Gross- und Mittelformattechnik bei der Roentgendiagnostik der weiblichen Harninkontinenz

Publishing Information

Journal Title
Radiol. Diagn.
Journal Volume
28
Journal Issue
3
Series
Radiol. Diagn.
Journal Page Range
427-435
ISSN
0033-8354
CODEN
RDGNA