Published June 2018 | Version v1
Journal article

Safety classification of structures, systems and components in HPR1000 based on ANSI/ANS 58.14

  • 1. Hualong International Nuclear Power Technology Ltd., Beijing (China)

Description

As the Generation III Nuclear Power Plants, HPR1000 not only meets the requirements of domestic nuclear safety codes and standards , but also international standards, such as IAEA SSG-30. In fact, HPR1000 is to be faced more safety reviews when exports abroad. Safety classification of structures, systems and components in HPR1000 is also an important area when safety reviewed. A new methodology of safety classification based on ANSI/ANS 58.14 is to be investigated and developed with some experiences considered. As a result, safety classification of HPR1000 obeying to ANSI/ANS 58.14 is basically feasibility, without essential improvements. (authors)

Additional details

Publishing Information

Journal Title
Chinese Journal of Nuclear Science and Engineering
Journal Volume
38
Journal Issue
3
Journal Page Range
p. 523-531
ISSN
0258-0918

Optional Information

Notes
4 figs., 9 tabs., 3 refs.