Published February 1985 | Version v1
Report Restricted

Sequoyah equipment hatch seal leakage. Final report, February 1985

Description

The Sequoyah equipment hatch should not leak before strains of several percent develop in the 1/2-inch containment shell plate near the springline, which occurs between 50 and 60 psi. In the unlikely event of hatch buckling, postbuckling deformations would not introduce leakage

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 - GPO as TI85011358.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
45 p.
Report number
NUREG/CR--3952

Optional Information

Secondary number(s)
IS--4862.