Estimate of organ radiation absorbed doses in clinical CT using the radiation treatment planning system
Creators
- 1. Dept. of Radiological Sciences, School of Health Sciences, Ibaraki Prefectural Univ., Ami, Ami-machi, Inashiki-gun, Ibaraki 300-0394 (Japan)
- 2. Graduate School of Comprehensive Human Sciences, Univ. of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan)
- 3. Dept. of Cardiovascular Science and Medicine, Chiba Univ. Graduate School of Medicine, 14-8-1 Inohana, Chuou-ku, Chiba 260-8687 (Japan)
- 4. Div. of Radiology and Biomedical Engineering, Graduate School of Medicine, The Univ. of Tokyo, Bunkyo-ku, Tokyo 113-8655 (Japan)
- 5. Dept. of Radiology, Chiba Univ. Hospital, 1-8-1 Inohana, Chuou-ku, Chiba 260-8687 (Japan)
- 6. Medical Physics and Bioengineering Dept., Christchurch Hospital, Private Bag 4710, Christchurch, New Zealand School of Medicine, Tokai Univ., 143 Shimokasuya, Isehara-shi, Kanagawa 259-1193 (Japan)
Description
Organ absorbed doses in computed tomography (CT) scans can be measured with anatomical phantoms but not inside the human body. In this study, a straightforward method was investigated to estimate organ doses in clinical CT using the radiation treatment planning system (RTPS) and compared them with experimental results of photoluminescence dosemeters (PLD). In a heterogeneous phantom, the average difference between PLD and RTPS values were 25.0% for the body and 7.1% for the lung. Using CT data, organ doses in 30 clinical cases were then calculated. There was a significant inverse correlation between the calculated values of organ doses and body mass index (BMI, correlation coefficients (r)520.69 (whole body), 20.80 (right lung), 20.81 (left lung), 20.76 (spinal cord), 20.74 (vertebra bone), 20.74 (heart), and 20.79 (oesophagus), all p < 0.01). An RTPS can be a simple and useful tool for estimating equivalent doses inside the human body, during whole-body CT scans. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncq188Additional details
Identifiers
- DOI
- 10.1093/rpd/ncq188;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 142
- Journal Issue
- 2-4
- Journal Page Range
- p. 174-183
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 43102114
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CAT SCANNING; COMPUTERS; DOSE EQUIVALENTS; DOSES; ESOPHAGUS; HEART; HUMAN POPULATIONS; LASER RADIATION; LUNGS; MASS; MONTE CARLO METHOD; PHANTOMS; PHOTOLUMINESCENCE; PULSED IRRADIATION; RADIATION PROTECTION; RADIOTHERAPY; SPINAL CORD; VERTEBRAE; WHOLE-BODY IRRADIATION; X RADIATION
- Descriptors DEC
- BODY; CALCULATION METHODS; CARDIOVASCULAR SYSTEM; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; ELECTROMAGNETIC RADIATION; EMISSION; EXTERNAL IRRADIATION; IONIZING RADIATIONS; IRRADIATION; LUMINESCENCE; MEDICINE; MOCKUP; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; PHOTON EMISSION; POPULATIONS; RADIATIONS; RADIOLOGY; RESPIRATORY SYSTEM; SKELETON; STRUCTURAL MODELS; THERAPY; TOMOGRAPHY
Optional Information
- Notes
- 28 refs