Humidification Dehumidification Spray Column Direct Contact Condenser Part I: Countercurrent Flow
Description
Humidification-dehumidification (HDH) is a low grade energy desalination technology. The waste heat from power plant (such NPP) can be used as heat source to preheat water (in evaporator) and air (in condenser) . Hot humid air and cooled spray water in counter current flow with direct contact is theoretically analyzing in the present work. Direct contact spray condenser is studied to provide the effect of various parameters on its performance. A computer programme describing the theoretical model is designed to solve a one-dimensional differential equations by using Rung–Kutta method. The programme predicts the droplet radius, velocity and temperature, besides, the humidity and temperature of air. The results show that, the length of column has great effect on the performance of spray condenser. At column height of 0.762, 2, 5, 10, and 20 m the humidity of the output air decreases by 50%, 72%, 89%, 97%, and 99% respectively. The condensate increases about 35% when the length increase from 5 to 10 m at ΔT = 25°C while increase only 18% at ΔT = 30°C. Also, it is found that, at ΔT = 25°C the condensate decrease from H = 10 to 5 m about 31% and increases from 10 to 20 m about 32%. While these results for ΔT = 25°C are 32% from H = 10 to 5 m and 36% from 10 to 20 m.The increase of both water and air mass fluxes increases the condensate mass flow rate. (author)
Files
48036377.pdf
Files
(135.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:91b66a679ee028efb61c9a491c952d9f
|
135.2 kB | Preview Download |
Additional details
Identifiers
Publishing Information
- Imprint Title
- 23rd WiN Global Annual Conference: Women in Nuclear meet Atoms for Peace. Programme and Abstracts
- Imprint Pagination
- 227 p.
- Journal Page Range
- p. 147
- Report number
- IAEA-CN--221
Conference
- Title
- 23. WiN Global Annual Conference: Women in Nuclear meet Atoms for Peace
- Acronym
- WiN-2015
- Dates
- 24-28 Aug 2015
- Place
- Vienna (Austria)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48036377
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPRESSORS; CONDENSATES; COUNTER CURRENT; DEHYDRATION; DESALINATION; DESIGN; DIFFERENTIAL EQUATIONS; DROPLETS; DRYING; EVAPORATORS; FLOW RATE; HEAT EXCHANGERS; HEAT SOURCES; HEIGHT; HUMIDITY; NUCLEAR POWER PLANTS; SPRAYS; VAPOR CONDENSERS; WASTE HEAT
- Descriptors DEC
- DEMINERALIZATION; DIMENSIONS; ENERGY; EQUATIONS; HEAT; MOISTURE; NUCLEAR FACILITIES; PARTICLES; POWER PLANTS; SEPARATION PROCESSES; THERMAL POWER PLANTS; WASTES
Optional Information
- Notes
- Poster presentation
- Secondary number(s)
- WiN-2015--145