Published November 1, 2010 | Version v1
Journal article

Water equivalency evaluation of PRESAGE dosimeters for dosimetry of Cs-137 and Ir-192 brachytherapy sources

Description

A major challenge in brachytherapy dosimetry is the measurement of steep dose gradients. This can be achieved with a high spatial resolution three dimensional (3D) dosimeter. PRESAGE is a polyurethane based dosimeter which is suitable for 3D dosimetry. Since an ideal dosimeter is radiologically water equivalent, we have investigated the relative dose response of three different PRESAGE formulations, two with a lower chloride and bromide content than original one, for Cs-137 and Ir-192 brachytherapy sources. Doses were calculated using the EGSnrc Monte Carlo package. Our results indicate that PRESAGE dosimeters are suitable for relative dose measurement of Cs-137 and Ir-192 brachytherapy sources and the lower halogen content PRESAGE dosimeters are more water equivalent than the original formulation.

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/250/1/012093

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
250
Journal Issue
1
Journal Page Range
[5 p.]
ISSN
1742-6596

Conference

Title
6. international conference on 3D radiation dosimetry
Acronym
IC3DDose
Dates
22-26 Aug 2010
Place
Hilton Head Island, SC (United States)