Published April 1998 | Version v1
Journal article

A comparative study of 234U/238U alpha-activity ratios determined by alpha-spectrometry and calculated from mass spectrometric data

  • 1. Bhabha Atomic Research Centre, Bombay (India). Fuel Chemistry Div.

Description

234U/238U α-activity ratios determined by α-spectrometry (AS) and those calculated from the atom ratio data using the half-life values are compared in some of the isotopic reference materials of uranium and a few other uranium samples. For α-spectrometry, electrodeposited sources were prepared and a large area passivated ion implanted (IPE) detector (450 mm2) was used for recording the α-spectra. The isotopic composition of U was determined by thermal ionisation mass spectrometry (TIMS) and the recommended half-life values of 234U and 238U were used to calculate the α-activity ratio. It is observed that 234U/238U α-activity ratios calculated from the atom ratio data are consistently high, with a mean difference of about 5%, when compared to the α-spectrometry results. This discrepancy warrants confirmation by a few more laboratories and suggests redetermination of the half-life values of 234U and 238U. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
230
Journal Issue
1-2
Journal Page Range
p. 265-267.
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
8 refs.