A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

  • 1. Physics Department, Queensland University of Technology, Brisbane (Australia)
  • 2. Texas Oncology Tyler, Radiation Oncology Department, 910 East Houston Street, Tyler 75703, TX (United States)
  • 3. East Texas Medical Center, Radiation Oncology Department, ETMC_Cancer Institute, 721 Clinic Drive, Tyler 75701, TX (United States)

Description

The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence

Availability note (English)

Available from http://dx.doi.org/10.1186/1748-717X-7-49; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3337228

Additional details

Publishing Information

Journal Title
Radiation Oncology (Online)
Journal Volume
7
Journal Page Range
p. 49
ISSN
1748-717X

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47061845
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; IMAGES; LIGHT SOURCES; LINEAR ACCELERATORS; QUALITY ASSURANCE; RADIOTHERAPY; TOOLS; VISIBLE RADIATION
Descriptors DEC
ACCELERATORS; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; EQUIPMENT; MEDICINE; NUCLEAR MEDICINE; RADIATION SOURCES; RADIATIONS; RADIOLOGY; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c)2012 Njeh et al
Notes
PMCID: PMC3337228; PUBLISHER-ID: 1748-717X-7-49; PMID: 22452821; OAI: oai:pubmedcentral.nih.gov:3337228; licensee BioMed Central Ltd.