Published October 1985
| Version v1
Journal article
Muon beam polarization at the LAMPF biomedical channel
- 1. Los Alamos National Laboratory, Los Alamos, NM
Description
Recent modifications to the LAMPF Biomedical Channel have improved versatility for stopping pion and muon physics experiments. High muon polarization was achieved by favorable kinematic selection of the decay muons. This polarization has been measured and found to be close to the design expectation of about 85%. The Hanle method was employed to measure the polarization by observing left-right decay asymmetry at right angles to the beam with small precession fields (0-50 gauss). This technique is particularly suitable for high-intensity muon beams
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Nucl. Sci.
- Journal Volume
- NS-32
- Journal Issue
- 5
- Series
- IEEE Trans. Nucl. Sci.
- Journal Page Range
- 3338-3340
- ISSN
- 0018-9499
- CODEN
- IETNA
Conference
- Title
- Particle accelerator conference.
- Dates
- 13-16 May 1985.
- Place
- Vancouver (Canada).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17050986
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; HIGH ENERGY PHYSICS; IRRADIATION PLANTS; LAMPF LINAC; MEASURING METHODS; MUON BEAMS; MUONS; PIONS; POLARIZATION; POLARIZED BEAMS; SPIN ORIENTATION
- Descriptors DEC
- ACCELERATORS; BEAMS; BOSONS; DIAGNOSTIC TECHNIQUES; ELEMENTARY PARTICLES; FERMIONS; HADRONS; LEPTON BEAMS; LEPTONS; LINEAR ACCELERATORS; MEDICINE; MESON FACTORIES; MESONS; NUCLEAR FACILITIES; ORIENTATION; PARTICLE BEAMS; PHYSICS; PSEUDOSCALAR MESONS
Optional Information
- Secondary number(s)
- CONF-850504--.