Calculation of cross section of helium pipes for cryogenic systems
Description
System of evaluation of diameter of gas pipeline and thickness of AS walll was developed. Calculations were conducted for gas pipelines of 200 and 400 m length for cryogenic plants with different rate of liquid helium evaporation. Wall thickness was evaluated according to breaking strength conditions and registance to long crack formation under the effect of internal gas pressure in a tube, as well as to conditions of resistance to bearing by external pressure