Published 1989 | Version v1
Report Open

Calculation of cross section of helium pipes for cryogenic systems

Description

System of evaluation of diameter of gas pipeline and thickness of AS walll was developed. Calculations were conducted for gas pipelines of 200 and 400 m length for cryogenic plants with different rate of liquid helium evaporation. Wall thickness was evaluated according to breaking strength conditions and registance to long crack formation under the effect of internal gas pressure in a tube, as well as to conditions of resistance to bearing by external pressure

Availability note (English)

MF available from INIS under the Report Number.

Files

22070507.pdf

Files (488.3 kB)

Name Size Download all
md5:ba83758cb99810c1a80b7fb16917847a
488.3 kB Preview Download

System files (32.6 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Расчет сечения гелиевого газопровода для криогенных систем

Publishing Information

Imprint Pagination
12 p.
Report number
KFTI--89-25

INIS

Country of Publication
Ukraine
Country of Input or Organization
Ukraine
INIS RN
22070507
Subject category
S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
CRYOGENICS; EVAPORATION; HELIUM; LAMINAR FLOW; NUMERICAL SOLUTION; PIPES; THICKNESS; TURBULENT FLOW; VELOCITY
Descriptors DEC
DIMENSIONS; ELEMENTS; FLUID FLOW; NONMETALS; PHASE TRANSFORMATIONS; RARE GASES