Published January 1987 | Version v1
Journal article

A proven twin header design for small PWRs

  • 1. Foster Wheeler Power Products Ltd., London (UK)

Description

A unique design of PWR steam generator, developed by Foster Wheeler in Britain more than 30 years ago, avoids the problem of tubesheet sludge accumulation. The twin header steam generator uses a vertical, inverted U-tube bundle connected to cylindrical inlet and outlet headers. The advantages of the design and operating experience are outlined. (author)

Additional details

Publishing Information

Journal Title
Nucl. Eng. Int.
Journal Volume
32
Journal Issue
390
Series
Nucl. Eng. Int.
Journal Page Range
42
ISSN
0029-5507
CODEN
NEINB