Optimal Performance Simulation of a Metal Fiber Filter for Capturing Radioactive Aerosols
- 1. EcoEnergy Research Institute, Seoul (Korea, Republic of)
Description
In this study, the metal fiber filter used for removing radioactive aerosol is systematically dissected and studied in order to figure out the optimal design which can be applied to the actual operation conditions in nuclear heating, ventilation and air conditioning (HVAC) systems for particle collection. In order to derive the optimal design for metal fiber HEPA filter, a numerical model is developed and its results are compared to experimental data to test reliability. Moreover, sensitivity analysis is performed using important parameters to determine which parameters have large influence on the filter performance. Using the model developed in this study, optimal design parameters for pleated metal fiber filters are derived which include fiber diameter less than 4 μm, solidity larger than 0.2, filter thickness larger than 1 mm, and face velocity lower than 5 cm/s. With these conditions, the metal filter qualified for the HEPA filter standard which specified 99.97% efficiency in the 0.3 μm particle size range.
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS 2016 spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [4 p.]
Conference
- Title
- 2016 spring meeting of the KNS
- Dates
- 11-13 May 2016
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 48048667
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- AEROSOLS; COMPUTERIZED SIMULATION; FIBERS; FILTERS; PERFORMANCE; PRESSURE DROP; SENSITIVITY; VELOCITY
- Descriptors DEC
- COLLOIDS; DISPERSIONS; SIMULATION; SOLS
Optional Information
- Notes
- 2 refs, 5 figs