Published March 2009 | Version v1
Journal article

Proof-of-Principle Time-Resolved Bremsstrahlung Spectral Measurement for Intense, Low-Endpoint (<300 keV) Pulsed Sources

  • 1. L-3 Communications/Pulse Sciences, San Leandro, CA 94577 (United States)
  • 2. Defense Threat Reduction Agency, Albuquerque, NM 87117 (United States)

Description

In a proof-of-principle test, we measured how the L-3 Pulse Sciences MBS (∼200 keV peak voltage) Bremsstrahlung spectrum changed in time using a pair of filter-fluorescer channels, one at 41 ± 18 keV and another at 87 ± 27 keV. This demonstrates an approach for measuring a time-resolved bremsstrahlung spectrum for SGEMP applications, albeit with coarse energy resolution (30-45%). Using filter fluorescers and detecting the resultant X-rays with plastic scintillator PMTs, there is adequate sensitivity and dynamic range to correlate spectra from two sources, MBS and PITHON, which differ by a factor of up to ∼100x in brightness (from 1 to 100 rad CaF2 at the spectrometer entrance). For such a correlation, no hardware changes are required-only the PMT gains need to be changed. The time resolution of the measurement is expected to be 2 ns.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/4/03/P03007

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
4
Journal Issue
03
Journal Page Range
p. P03007
ISSN
1748-0221