Published March 2007 | Version v1
Journal article

Correction of thickness measurement errors for two adjacent sheet structures in MR images

  • 1. Harbin Inst. of Technology, Robot Research Inst., Harbin, Heilongjiang (China)
  • 2. Osaka Univ., Graduate School of Medicine, Suita, Osaka (Japan)

Description

We present a new method for measuring the thickness of two adjacent sheet structures in MR images. In the hip joint, in which the femoral and acetabular cartilages are adjacent to each other, a conventional measurement technique based on the second derivative zero crossings (called the zero-crossings method) can introduce large underestimation errors in measurements of cartilage thickness. In this study, we have developed a model-based approach for accurate thickness measurement. We model the imaging process for two adjacent sheet structures, which simulate the two articular cartilages in the hip joint. This model can be used to predict the shape of the intensity profile along the sheet normal orientation. Using an optimization technique, the model parameters are adjusted to minimize the differences between the predicted intensity profile and the actual intensity profiles observed in the MR data. The set of model parameters that minimize the difference between the model and the MR data yield the thickness estimation. Using three phantoms and one normal cadaveric specimen, the usefulness of the new model-based method is demonstrated by comparing the model-based results with the results generated using the zero-crossings method. (author)

Additional details

Publishing Information

Journal Title
Medical Imaging Technology
Journal Volume
25
Journal Issue
2
Journal Page Range
p. 99-110
ISSN
0288-450X