Published September 1983 | Version v1
Journal article

Thermal and mechanical design of a doublewalled steam generator

  • 1. Babock and Wilcox Co., Power Generation Group, P.O. Box 1250, Lynchburg, VA 24505

Description

A double-walled steam generator is used in the fusion power cycle to replace the intermediate loop. This will save the cost associated with a complicated system and the associated temperature degradation. The mechanical design of the steam generator is similar to that proposed for LMFBR application. The heat transfer and tritium diffusion calculations are performed. The double-walled steam generator provides a tritium diffusion barrier factor > 105 while increasing the surface area by 25% compared to a singlewalled steam generator

Additional details

Publishing Information

Journal Title
Nucl. Technol./Fusion
Journal Volume
4
Journal Issue
2
Series
Nucl. Technol./Fusion.
Journal Page Range
1509-1513
ISSN
0272-3921

Conference

Title
5. topical meeting on technology of fusion energy.
Dates
26-28 Apr 1983.
Place
Knoxville, TN (USA).

Optional Information

Secondary number(s)