Magnetic field alignment studies for the URAGAN-3 torsatron
Creators
- 1. Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Description
If the major axes of the helical and vertical field coils of a torsatron plasma confinement device are not aligned to within approx. 1% of their major radii, the resulting error field can break up closed magnetic flux surfaces and reduce the effective plasma confinement volume. A novel technique for accurately locating the magnetic symmetry axes of torsatron helical and vertical coil sets to within approx. 1 mm using magnetic field measurements near the device major axis (i.e., away from the confinement volume) is described and applied to the URAGAN-3 torsatron. The axis of the vertical field coil set was found to be shifted by approx. 1 cm relative to the axis of the helical coil set; this shift could account for the reduced confinement volume observed in previous experiments. The magnetic measurements were repeated after coil repositioning to verify correct alignment
Additional details
Publishing Information
- Journal Title
- Rev. Sci. Instrum.
- Journal Volume
- 57
- Journal Issue
- 7
- Series
- Rev. Sci. Instrum.
- Journal Page Range
- 1233-1241
- ISSN
- 0034-6748
- CODEN
- RSINA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17070789
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ALIGNMENT; MAGNET COILS; MAGNETIC FIELD CONFIGURATIONS; MAGNETIC FIELDS; MAGNETIC FLUX; PLASMA CONFINEMENT; URAGAN STELLARATOR
- Descriptors DEC
- CLOSED PLASMA DEVICES; CONFINEMENT; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; STELLARATORS; THERMONUCLEAR DEVICES