Published March 2006 | Version v1
Journal article

Monte Carlo simulation of radiation dose distribution of γ-ray density meter

  • 1. Anhui Univ., Hefei (China). School of Electronic Science and Technology
  • 2. China Science and Technology Univ., Hefei (China). Dept. of Modern Physics

Description

As an example, the authors have calculated the radiation dose distribution near by a γ-ray density meter equipped in a 1600 type dredge ship, using Geant 4 (Monte Carlo simulation software). The most serious radiation leakage is found in the region close to the detector and it's safe for using the γ-ray density meter under normal working condition. But under some abnormal condition such as the empty pipe, the density meter will detect a huge amount of radiation. For providing a safe circumstance, additional shield should be adopted. In fact a piece of steel plate of φ50 cm x 7 cm in thickness could prevent most of escaping radiation and ensure the safety. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
29
Journal Issue
3
Journal Page Range
p. 178-181
ISSN
0253-3219

Optional Information

Notes
7 figs., 6 refs.