Qualification test of DL123 neutron ionization chamber in nuclear power plant reactor
Creators
- 1. Beijing Nuclear Instrument Factory, Beijing (China)
- 2. NPQJVC, Haiyan (China)
Description
This paper introduces the examine content and test data about type DL123 neutron ionization chamber operating in nuclear power plant reactor, and compare with type CBL-26 neutron ionization chamber using in reactor. Type DL123 neutron ionization chamber operates steady and reliable in one exchange fuel cycle (about one year). (authors)
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 6th national conference on nuclear instrument and its application
- Imprint Pagination
- 174 p.
- Journal Page Range
- p. 131-137
Conference
- Title
- 6. national conference on nuclear instrument and its application
- Dates
- 5-11 Nov 2007
- Place
- Guilin, Guangxi (China)
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 43021236
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature, Numerical Data
- Descriptors DEI
- COMPARATIVE EVALUATIONS; EXPERIMENTAL DATA; FUEL CYCLE; IONIZATION CHAMBERS; NEUTRONS; NUCLEAR POWER PLANTS; PERFORMANCE TESTING; REACTORS; STABILITY
- Descriptors DEC
- BARYONS; DATA; ELEMENTARY PARTICLES; EVALUATION; FERMIONS; HADRONS; INFORMATION; MEASURING INSTRUMENTS; NUCLEAR FACILITIES; NUCLEONS; NUMERICAL DATA; POWER PLANTS; RADIATION DETECTORS; TESTING; THERMAL POWER PLANTS
Optional Information
- Notes
- 3 figs., 9 tabs., 2 refs.