Published December 2018 | Version v1
Journal article

Estimation of adult patient doses for chest X-ray examinations and comparison with diagnostic reference levels (DRLs)

  • 1. Cekmece Nuclear Research and Training Center -CNAEM-, 34303 Istanbul (Turkey)
  • 2. Istanbul Technical University -ITU-, Institute of Energy, Ayazaga Kampusu, 34469 Istanbul (Turkey)
  • 3. Turkish Ministry of Health, Istanbul Health Directorate, 34122 Istanbul (Turkey)

Description

The aim of this study was to evaluate the radiation doses to patient during chest (posterior anterior/and lateral) examinations. The study was performed in three public hospitals of Istanbul province with a total of 300 adult patients. Entrance surface dose (ESD) measurements were conducted on computed radiography, digital radiography and screen film system. ESD was estimated by using International Atomic Energy Agency (IAEA) model and Davies model which are the common indirect models. Results were compared with diagnostic reference levels from the European Commission, IAEA and National Radiological Protection Board. Although the results are compatible with the international diagnostic reference levels, they present variations between the hospitals. Dose variations for the same type of X-ray examination support the idea that further optimization is possible. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncy076

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
182
Journal Issue
3
Journal Page Range
p. 377-385
ISSN
0144-8420

Optional Information

Notes
23 refs.