Indium-111 white blood cell scans: Sensitivity, specificity, accuracy, and normal patterns of distribution
Creators
Description
The UCLA Hospital experience with indium-111 labeled white blood cells was reviewed. There were a total of 345 consecutive cases covering a broad range of clinical indications. The overall sensitivity of the method was 79%, specificity was 62%, and accuracy was 73%. The sensitivity for suspected osteomyelitis cases was 84%, with a specificity of 65% and an accuracy of 75%. For other cases sensitivity was 77%, specificity was 60%, and accuracy was 72%. Furthermore, patterns of normal distribution were reviewed
Additional details
Publishing Information
- Journal Title
- Clinical Nuclear Medicine
- Journal Volume
- 15
- Journal Issue
- 1
- Series
- Clin. Nucl. Med.
- Journal Page Range
- 8-10
- ISSN
- 0363-9762
- CODEN
- CNMED
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 21058671
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; DIAGNOSIS; INDIUM 111; INFLAMMATION; LEUKOCYTES; OSTEOMYELITIS; RADIOISOTOPE SCANNING; SENSITIVITY ANALYSIS; SPECIFICITY
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BIOLOGICAL MATERIALS; BLOOD; BLOOD CELLS; BODY FLUIDS; COUNTING TECHNIQUES; DAYS LIVING RADIOISOTOPES; DISEASES; ELECTRON CAPTURE RADIOISOTOPES; INDIUM ISOTOPES; INTERMEDIATE MASS NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MATERIALS; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-EVEN NUCLEI; PATHOLOGICAL CHANGES; RADIOISOTOPES; SKELETAL DISEASES