Published 1987 | Version v1
Report Open

Argon cover gas purity control on LMFBR

  • 1. PNC (JP)
  • 2. Toshiba (JP)
  • 3. Hitachi (JP)

Description

Various control methods on chemical impurities and radioactive materials (fission products) in the primary argon gas of LMFBRs' have been studied based on experiences in Joyo and results of research and development. These results are reflected on MONJU design. On-line gas chromatographs are installed both in the Primary and in the Secondary Argon Gas Systems in JOYO. Also, chemical analysis has been done by batch sampling in JOYO. Though the rise of impurity concentration had been measured after periodical fuel exchange operation, impurity concentration has been controlled sufficiently under target control limits. In MONJU detailed design, the Rare Gas Removal and Recovery System which consisted of cryogenic distillation equipment had been eliminated and the capacity of Charcoal Beds in the Primary Argon Gas System has been improved to keep the concentration of radioactive materials sufficient low levels. The necessity to control the impurities in fresh argon gas which is supplied to the Primary Argon Gas System is now considered to keep the concentration of Kr and Xe isotopes in specified level, because their isotopes may make background rise for the Tagging Gas Failed Fuel Detection and Location System. Based on various investigations performed on sodium vapor trapping to obtain its detailed characteristics, design specifications and operating conditions of MONJU's Vapor Traps have been decided. To keep the level of radioactivity in gaseous effluents to the environment as low as reasonably achievable, the following means are now adopted in MONJU: the Primary Argon Gas System is composed of a closed recirculating path, but the exhaust gas discharged has different path after the Charcoal Beds; fresh argon gas is blown down to prevent Primary Argon Gas from releasing to the circumference during opening of the primary argon gas boundary, such as fuel exchange operations. (author)

Files

33011385.pdf

Files (547.6 kB)

Name Size Download all
md5:96d72153fc4cc3589daba73a8addb3cc
547.6 kB Preview Download
Part of:
Specialists' meeting on fast reactor cover gas purification

Additional details

Publishing Information

Imprint Title
Specialists' meeting on fast reactor cover gas purification
Imprint Pagination
288 p.
Journal Page Range
p. 123-160
Report number
IWGFR--61

Conference

Title
IAEA-IWGFR specialists' meeting on fast reactor cover gas purification
Dates
24-26 Sep 1986
Place
Richland, WA (United States)

Optional Information

Notes
4 figs, 4 tabs