Published May 2018 | Version v1
Journal article

An extractive pellet fluorimetric determination of trace uranium in thorium rich samples

  • 1. Atomic Minerals Directorate for Exploration and Research, Eastern Region, AMD Complex, Khasmahal, Jamshedpur (India). Chemical Laboratory, Department of Atomic Energy

Description

An extractive pellet fluorimetry determination of trace uranium in thorium rich samples has been developed. This is based upon a solvent extraction system which completely separates both the elements uranium and thorium from each other. Thorium as a neutral complex with 2,3-dihydroxynaphthalene at pH 4-6 is extracted into ethylacetate and then uranium-2,3-dihydroxynaphthalene anionic complex is extracted into another batch of ethylacetate at pH 11-12 under the influence of a counter cation, cetyltrimethylammonium ion. This method has been applied for the determination of trace uranium in synthetic nuclear grade thorium oxide and thorium rich mineralized rock with high degree of accuracy and precision. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
316
Journal Issue
2
Journal Page Range
p. 527-534
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
17 refs.