Published March 1, 2019 | Version v1
Journal article

The effect of steel ball diameter variation in dry shot peening process on surface roughness and corrosion rate of AISI 316L implant material

  • 1. Department of Mechanical Engineering, University of Trunojoyo Madura (Indonesia)
  • 2. Department of Electrical Engineering, University of Trunojoyo Madura (Indonesia)
  • 3. Department of Informatics Engineering, University of Trunojoyo Madura (Indonesia)
  • 4. Department of Mechanical Engineering, Brawijaya University, Malang (Indonesia)

Description

Stainless steel, or also called as inox steel is a material that has a resistivity to the oxide reaction in an oxygen-containing environment. This study uses AISI 316L stainless steel material which is a biomedical implant as a raw material that obtains surface modification technique to obtain new mechanical properties. Surface modification technique uses dry shot peening process by varying steel ball diameter as an abrasive material shot on the surface of steel ball at high speed. The steel ball used is AISI 440 C type with a hardness level of HRC 50-55. The results show that the level of material surface roughness will decrease along with the increasing (bigger) size of steel ball diameter used. The results of corrosion test on SBF solution (simulated body fluid) show an increase in corrosion resistance along with the decreasing (smaller) size of steel ball diameter used. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1757-899X/494/1/012092

Additional details

Publishing Information

Journal Title
IOP Conference Series. Materials Science and Engineering (Online)
Journal Volume
494
Journal Issue
1
Journal Page Range
[6 p.]
ISSN
1757-899X

Conference

Title
International Conference on Mechanical Engineering Research and Application
Dates
23-25 Oct 2018
Place
Malang (Indonesia)