Published 1975 | Version v1
Report

On diagnostic techniques for optically non-transparent superdense plasma

  • 1. AN Ukrainskoj SSR, Kharkov. Fiziko-Tekhnicheskij Inst.

Description

Possibilities are considered of optical, X-ray, magneto-probe methods for diagnostics of plasma of pulse high-current gas discharges at superhigh pressures (100-1000 at). Some results are presented on applying the methods, the method for measuring pulsed pressures during the discharge, the method of axial X-raying and measuring the electric conductivity of a dense plasma. The conductivity of argon and copper arc plasma has been measured by the method of axial X-raying at the pressure up to 1000 at and at the value of the Coulomb logarithm 1-3. A formula is derived which allows one to estimate the electric conductivity value for a dense non-ideal plasma to an accuracy of 50% in a very wide range of its parameters

Additional details

Additional titles

Original title (Russian)
О методах диагностики сверхплотной оптически непрозрачной плазмы

Publishing Information

Imprint Title
Plasma physics and the controlled thermonuclear fusion physics
Imprint Pagination
p. 52-59.
Journal Issue
no. 1(3
Series
Voprosy atomnoj nauki i tekhniki.
Report number
KFTI--75-19

Optional Information

Notes
24 refs.; 5 figs.; 2 tables. Imprint:Fizika plazmy i problemy upravlyaemykh termoyadernykh reaktsij.