Diagnostic system and diagnostic experiences at the Paks Nuclear Power Plant

  • 1. Paksi Atomeroemue Vallalat (Hungary)

Description

The major functions of the diagnostic system of the first two units of the Paks Nuclear Power Plant are as follows: monitoring the mechanical integrity of the reactor and the primary coolant circuit by means of vibration diagnostics; leakage detection of the primary coolant circuit by means of high frequency sonic analysis; loose parts monitoring based on the analysis of high frequency signals of acceleration detectors; and monitoring the vibration state of the turbines and rotary machines by the latter method or by a procedure based on the detection of mechanical vibrations. Up-to-date vibration diagnostics is based on the information supplied by either acceleration detectors or pressure fluctuation detectors, or in-core and ex-core neutron detectors. (V.N.)

Additional details

Additional titles

Original title (Hungarian)
A Paksi Atomeroemue diagnosztikai rendszere es diagnosztikai tapasztalatok

Publishing Information

Journal Title
Magy. Villamos Muevek Troeszt Koezl.
Journal Volume
23
Journal Issue
5
Series
Magy. Villamos Muevek Troeszt Koezl.
Journal Page Range
18-23
ISSN
0133-0926
CODEN
MVMKD

Optional Information

Notes
4 figs.