Published 1975 | Version v1
Report Open

Nuclear yield determinations using isotope-separator-on-line arrangements

Description

The delay between the formation of a nuclear reaction product and its collection in front of measuring equipment in ISOL arrangements using integrated target-ion source systems has been analyzed. It is shown that a typical delay function takes the form const x (1-esup(-γt))esup(-μt) with γ >> μ. The results can be used for decay corrections in nuclear yield determinations. (Auth.)

Availability note (English)

MF available from INIS under the Report Number.

Files

7237898.pdf

Files (516.9 kB)

Name Size Download all
md5:1e1f2f264d0fd6e057134d95a1957560
516.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
27 p.
Report number
LF--65