Published 1987
| Version v1
Book
Liquid-argon ionization chambers as total absorption detectors
Creators
Description
A new detector for the measurement of energy by total absorption, based on the use of multiple-plate ion chambers, is described. The use of liquid argon as the working medium and optimized readout results in an electronic noise contribution to the resolution of less than 0.1 GeV, in a large detector. The use of thin plates, 0.1 radiation length, ensure that sampling fluctuations are small. The technique allows absolute calibration and very good gain stability. Tests on a detector large enough to absorb a high-energy electromagnetic shower are described, where the energy resolution is limited by the residual sampling fluctuations
Additional details
Publishing Information
- Publisher
- Addison-Wesley Pub. Co. Inc.
- Imprint Place
- Reading, MA (USA)
- Imprint Title
- Experimental techniques in high energy physics
- Journal Page Range
- p. 497-534.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20035101
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ARGON; CALIBRATION; FLUCTUATIONS; IONIZATION CHAMBERS; PLATES; SAMPLING
- Descriptors DEC
- ELEMENTS; MEASURING INSTRUMENTS; NONMETALS; RADIATION DETECTORS; RARE GASES; VARIATIONS