Published August 1, 1996 | Version v1
Journal article

Performance of a coaxial geometry Cd1-xZnxTe detector

  • 1. Sandia Nat. Labs., Livermore, CA (United States)
  • 2. eV Products, a Division of II-VI Incorporated, Saxonburg, PA 16056 (United States)

Description

For many years, coaxial geometry detectors have been the preferred configuration for large volume high purity germanium detectors. Recently, developments in Cd1-xZnxTe crystal growth and detector fabrication have enabled the construction of coaxial geometry Cd1-xZnxTe detectors for the first time. We report on the performance of a coaxial geometry Cd1-xZnxTe detector operated as a gamma ray spectrometer. The pulse height spectra obtained from this detector were analyzed using a theory developed by Sakai for use with germanium detectors and good agreement was obtained between the predictions of Sakai's theory and the results measured in our laboratory. We also comment on some possible improvements that could be made to future coaxial geometry Cd1-xZnxTe detectors. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
377
Journal Issue
2-3
Journal Page Range
p. 479-483.
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
7. European symposium on semiconductor detectors, new developments in radiation detectors.
Dates
7-10 May 1995.
Place
Schloss Elmau (Germany).

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
27068880
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CDTE SEMICONDUCTOR DETECTORS; GAMMA DETECTION; GAMMA SPECTROMETERS; KEV RANGE 100-1000; PULSES
Descriptors DEC
DETECTION; ENERGY RANGE; KEV RANGE; MEASURING INSTRUMENTS; RADIATION DETECTION; RADIATION DETECTORS; SEMICONDUCTOR DETECTORS; SPECTROMETERS