Published 1985
| Version v1
Report
Restricted
Cavity-coupling investigation for the PHERMEX 50 MHz rf accelerator
Description
The PHERMEX accelerator is a three-cavity rf linac that operates at 50 MHz. Each cavity has a radius of 2.3 m and a length of 2.6 m. The accelerator produces an electron beam with a peak current of 500 A and energy of 30 MeV. The rf power is supplied by multiple 2.5-MW tetrodes feeding coaxial lines with loops in the cavity wall. To increase the fields, multiple tetrodes and coupling loops must be used in each cavity; the problems associated with multiple-loop coupling are investigated. 3 refs., 4 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE85012704.
Files
Additional details
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- LA-UR--85-1656
Conference
- Title
- Particle accelerator conference.
- Dates
- 13-16 May 1985.
- Place
- Vancouver, British Columbia (Canada).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17006723
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CAVITY RESONATORS; COUPLING; ELECTRIC FIELDS; ELECTRON BEAMS; LINEAR ACCELERATORS; RF SYSTEMS
- Descriptors DEC
- ACCELERATORS; BEAMS; ELECTRONIC EQUIPMENT; EQUIPMENT; LEPTON BEAMS; PARTICLE BEAMS; RESONATORS
Optional Information
- Secondary number(s)
- CONF-850504--92.