Structural Evaluation of a PGSFR Steam Generator for a Steady State Condition
- 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
Description
In this study, design loads for design condition and normal operating steady state condition were classified and the structural analyses for each design loads were carried out. And, structural integrities under each service level were evaluated according to ASME design code. The structural analyses of a steam generator are carried out and its structural integrity under the given service levels is evaluated per ASME Code rule. The design loads according to design condition and normal operating steady condition are classified and stresses calculated from stress analyses are linearized and summarized in their stress components. As a result, the SG structure satisfies with design criteria for both service levels. Though the steam header is designed as a thick hemisphere, its design margin is not so high in spite of just steady state condition. Thus, additional evaluation by considering various operating events will be followed
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS 2015 spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [3 p.]
Conference
- Title
- 2015 spring meeting of the KNS
- Dates
- 6-8 May 2015
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 47022999
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- A CODES; COMPUTER CALCULATIONS; DESIGN; SODIUM COOLED REACTORS; STEAM GENERATORS; STRESS ANALYSIS; STRESSES
- Descriptors DEC
- BOILERS; COMPUTER CODES; LIQUID METAL COOLED REACTORS; REACTORS; VAPOR GENERATORS
Optional Information
- Notes
- 3 refs, 3 figs, 3 tabs