Published March 2008 | Version v1
Journal article

Stability analysis of a two-phase test loop

  • 1. Pennsylvania State University, 228 Reber Bldg., University Park, PA 16802 (United States)

Description

This paper presents an analytical model developed for investigating the stability characteristics of a low-pressure natural circulation test facility. The approach is to convert the two-phase flow system into a linear feedback system with respect to a steady-state operating point and linear theory is then applied to determine if the system would be stable around the operating point. The analysis results show that the stability of the system is sensitive to its inlet temperature and power level

Availability note (English)

Available from http://dx.doi.org/10.1016/j.anucene.2007.07.014

Additional details

Identifiers

DOI
10.1016/j.anucene.2007.07.014;
PII
S0306-4549(07)00174-0;

Publishing Information

Journal Title
Annals of Nuclear Energy (Oxford)
Journal Volume
35
Journal Issue
3
Journal Page Range
p. 525-533
ISSN
0306-4549
CODEN
ANENDJ

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
39067593
Subject category
S42: ENGINEERING;
Descriptors DEI
NATURAL CONVECTION; STABILITY; STEADY-STATE CONDITIONS; TEST FACILITIES; TWO-PHASE FLOW
Descriptors DEC
CONVECTION; ENERGY TRANSFER; FLUID FLOW; HEAT TRANSFER; MASS TRANSFER

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.