Main coolant piping (MCP) welding works at KKNPP

  • 1. Nuclear Power Corporation of India Limited, Mumbai (India)
  • 2. Kudankulam Nuclear Power Project, Kudankulam (India)

Description

The reactor coolant system or the Nuclear Steam Supply System (NSSS) consists of the Reactor Pressure Vessel (RPV), Main Coolant Pipeline (MCP), Reactor Coolant Pump (RCP), Steam Generator (SG), Emergency Core Cooling System (ECCS) stages 1 and 2, Quick Boron Injection System (QBIS), Pressuriser (PRZ), reactor internals and connections to the process parameter monitoring devices etc. The detailed technical planning and execution for welding of main coolant piping (MCP) are discussed in this article

Additional details

Publishing Information

Journal Title
Nu Power
Journal Volume
27
Journal Issue
1-2
Journal Page Range
p. 64-73
CODEN
NUPOEW

Optional Information

Notes
3 figs., 3 tabs.