Published September 1976 | Version v1
Journal article

Monitoring nuclear plant leakages

Creators

Description

The Monticello Nuclear Generating Plant, a unit of the Northern States Power Co., is using a sophisticated laboratory technique, i.e. a Varian Tectron 1200 atomic absorption spectrophotometer to analyse condensate taken from the plant's primary process water. The presence of magnesium is checked to monitor leakage of contaminants into the system from the cooling water system

Additional details

Publishing Information

Journal Title
Power Plant South. Afr.
Journal Issue
p. 23,25
Series