Evaluation of Gafchromic EBT2 film for the measurement of anisotropy function for high-dose-rate 192Ir brachytherapy source with respect to thermoluminescent dosimetry
- 1. Department of Radiology, Himalayan Institute of Medical Sciences, Jolly Grant, Dehradun (India)
- 2. Department of Physics, H N B Garhwal Central University, Campus Pauri, Pauri (Garhwal), Uttarakhand (India)
Description
Aim: The aim of this work was to assess the suitability of the use of a Gafchromic EBT2 film for the measurement of anisotropy function for micro Selectron HDR 192Ir (classic) source with a comparative dosimetry method using a Gafchromic EBT2 film and thermoluminescence dosimeters (TLDs). Background: Sealed linear radiation sources are commonly used for high dose rate (HDR) brachytherapy treatments. Due to self-absorption and oblique filtration of radiation in the source capsule material, an inherent anisotropy is present in the dose distribution around the source which can be described by a measurable two-dimensional anisotropy function, F(γ, Θ ). Materials and methods: Measurements were carried out in a specially designed and locally fabricated PMMA phantom with provisions to accommodate miniature LiF TLD rods and EBT2 film dosimeters at identical radial distances with respect to the 192Ir source. Results: The data of anisotropy function generated by the use of the Gafchromic EBT2 film method are in agreement with their TLD measured values within 4%. The produced data are also consistent with their experimental and Monte Carlo calculated results for this source available in the literature. Conclusion: Gafchromic EBT2 film was found to be a feasible dosimeter in determining anisotropy in the dose distribution of 192Ir source. It offers high resolution and is a viable alternative to TLD dosimetry at discrete points. The method described in this paper is useful for comparing the performances of detectors and can be applied for other brachytherapy sources as well. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Reports of Practical Oncology and Radiotherapy
- Journal Volume
- 16
- Journal Issue
- 1
- Series
- 17 refs., 3 figs., 3 tabs.
- Journal Page Range
- p. 14-20
- ISSN
- 1507-1367
INIS
- Country of Publication
- Poland
- Country of Input or Organization
- Poland
- INIS RN
- 42099593
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANISOTROPY; DOSIMETRY; ENERGY BEAM DEPOSITION; IRIDIUM 192; IRRADIATION; PHANTOMS; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; DAYS LIVING RADIOISOTOPES; DEPOSITION; DOSEMETERS; ELECTRON CAPTURE RADIOISOTOPES; HEAVY NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IRIDIUM ISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; MOCKUP; NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; STRUCTURAL MODELS; SURFACE COATING; YEARS LIVING RADIOISOTOPES