Published June 1983 | Version v1
Journal article

Measurement of tracheal mucous transport rate in the horse

  • 1. Department of Veterinary Physiology and Pharmacology, College of Veterinary Medicine, Texas A and M University, College Station

Description

Tracheal mucous transport rates were measured in 12 nonanesthetized horses after an intratracheal injection of 99mtechnetium-sulfur colloid. The transport rate of the subsequent bolus of radioactivity was determined, using a portable scaler rate meter fitted with a high-energy gamma-scintillation probe. A gamma-scintillation camera was used to verify bolus form and movement in 1 horse. The mean tracheal mucous transport rate was 1.66 +/- 0.24 cm/min

Additional details

Publishing Information

Journal Title
Am. J. Vet. Res.
Journal Volume
44
Journal Issue
6
Series
Am. J. Vet. Res.
Journal Page Range
1165-1166
ISSN
0002-9645

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
15058764
Subject category
S60: APPLIED LIFE SCIENCES;
Descriptors DEI
HORSES; MUCOUS MEMBRANES; TECHNETIUM COMPOUNDS; TRACHEA
Descriptors DEC
ANIMALS; MAMMALS; RESPIRATORY SYSTEM; TRANSITION ELEMENT COMPOUNDS; VERTEBRATES